DC1030 Honeywell temperature controller
DC1030 instrument size (mm) length × wide × High 72 × seventy-two × ninety-four
Parameter Details Range
PV input type thermocouples (K, J, R, S, B, E, N, T, W, PL, U, L)
Thermal resistance (PT100 Ω, JPT100 Ω, JPT50 Ω)
Linear input (-10-10mv, 0-10mv, 0-20mv, 0-50mv, 10-50mv,
0-1v, 0-5v, 0-10v, 0-20ma, 1-5v, 2-10v, 4-20mA)
Input sampling time 250ms
Resolution 14 bits (per channel)
PV/SV display with 4 digits and 7-segment digital display
Non volatile memory in data storage systems
Display accuracy relative to full scale ± 0.2%
Control mode ratio band (P) 0-200% (P=0 when on/off control)
Integration time (I) 0-3600sec (I=0 during PD control)
Differential time (D) 0-900sec (D=0 during PI control)
Control output cycle 0-150sec (4-20mA → 0, solid-state relay → 1, electromechanical relay>10)
Deadband time 0-1000sec (Deadband time compensation)
Output relay output contact signal, single pole double throw switch signal, 3A/240VAC)
Voltage output pulse voltage, 20VDC/20mA
Linear output 4-20mA, 0-5V, 0-10V, 1-5V, 2-10V
Motor control output servo electric valve control
Other single-phase solid-state relays, three-phase solid-state relays, single-phase thyristor, three-phase thyristor
Three alarm channels (optional)
17 alarm types available for mode selection
Timer strobe alarm, continuous alarm, timer delay alarm
Auxiliary output signals SP, PV, MV
Output types 4-10mv, 0-20ma, 0-5v, 0-10v, 1-5v, 2-10v
Auxiliary input types 4-20mv, 0-20ma, 0-5v, 0-10v, 1-5v, 2-10v
Sampling period 250ms
Set the number of programs/segments 2/8 segments (each)
Capable of achieving functional set point programs that can be repeatedly called and interconnected/alarm output at the end of each program segment
Communication methods RS-232, RS-485 TTL
Parameter Details Range
PV input type thermocouples (K, J, R, S, B, E, N, T, W, PL, U, L)
Thermal resistance (PT100 Ω, JPT100 Ω, JPT50 Ω)
Linear input (-10-10mv, 0-10mv, 0-20mv, 0-50mv, 10-50mv,
0-1v, 0-5v, 0-10v, 0-20ma, 1-5v, 2-10v, 4-20mA)
Input sampling time 250ms
Resolution 14 bits (per channel)
PV/SV display with 4 digits and 7-segment digital display
Non volatile memory in data storage systems
Display accuracy relative to full scale ± 0.2%
Control mode ratio band (P) 0-200% (P=0 when on/off control)
Integration time (I) 0-3600sec (I=0 during PD control)
Differential time (D) 0-900sec (D=0 during PI control)
Control output cycle 0-150sec (4-20mA → 0, solid-state relay → 1, electromechanical relay>10)
Deadband time 0-1000sec (Deadband time compensation)
Output relay output contact signal, single pole double throw switch signal, 3A/240VAC)
Voltage output pulse voltage, 20VDC/20mA
Linear output 4-20mA, 0-5V, 0-10V, 1-5V, 2-10V
Motor control output servo electric valve control
Other single-phase solid-state relays, three-phase solid-state relays, single-phase thyristor, three-phase thyristor
Three alarm channels (optional)
17 alarm types available for mode selection
Timer strobe alarm, continuous alarm, timer delay alarm
Auxiliary output signals SP, PV, MV
Output types 4-10mv, 0-20ma, 0-5v, 0-10v, 1-5v, 2-10v
Auxiliary input types 4-20mv, 0-20ma, 0-5v, 0-10v, 1-5v, 2-10v
Sampling period 250ms
Set the number of programs/segments 2/8 segments (each)
Capable of achieving functional set point programs that can be repeatedly called and interconnected/alarm output at the end of each program segment
Communication methods RS-232, RS-485 TTL