LQ16P series single-phase power regulator
LQ16P is a new concept product for SCR application technology. It integrates single-phase voltage/power regulation methods. Equipped with power on slow start, slow shutdown, radiator overheating, suitable for resistive loads, it can be widely used for power adjustment in various industrial fields.
Main technical indicators:
4-20mA input: receiving impedance 120 Ω, adjusting output resolution: adjusting voltage by 0.6 °; Adjust the power for 20ms.
◆ Load mode: 50Hz single-phase 220VAC/380VAC Phase shift range: 0-175 °
◆ LED light status display: Green Input signal linear indicator light.
◆ Three color status light: RUN green running light; ALM red alarm light; The yellow flashing standby light of STOP.
◆ Automatic slow start and emergency stop during operation: Overcurrent and over temperature emergency stop during operation, with overcurrent and over temperature protection action time not exceeding one power cycle (20ms).
◆ 80 ℃ overtemperature protection: no voltage, normally closed contact open circuit: overtemperature release: after troubleshooting, reset the start stop switch or power on again.
◆ Power supply and synchronous source: 220VAC, 380VAC 50HZ (60HZ order declaration) 3W Insurance specification: 0.5A
◆ Alarm relay: A set of normally open contacts (pure resistance 1A 250VAC) Alarm type: radiator over temperature.
Main technical indicators:
4-20mA input: receiving impedance 120 Ω, adjusting output resolution: adjusting voltage by 0.6 °; Adjust the power for 20ms.
◆ Load mode: 50Hz single-phase 220VAC/380VAC Phase shift range: 0-175 °
◆ LED light status display: Green Input signal linear indicator light.
◆ Three color status light: RUN green running light; ALM red alarm light; The yellow flashing standby light of STOP.
◆ Automatic slow start and emergency stop during operation: Overcurrent and over temperature emergency stop during operation, with overcurrent and over temperature protection action time not exceeding one power cycle (20ms).
◆ 80 ℃ overtemperature protection: no voltage, normally closed contact open circuit: overtemperature release: after troubleshooting, reset the start stop switch or power on again.
◆ Power supply and synchronous source: 220VAC, 380VAC 50HZ (60HZ order declaration) 3W Insurance specification: 0.5A
◆ Alarm relay: A set of normally open contacts (pure resistance 1A 250VAC) Alarm type: radiator over temperature.